10 Important Product Information
GFK-1671P
Special Operational Notes
Opening VersaPro 1.x created folders
When opening VersaPro 1.x folders, the following dialog will be presented asking if you want to re-check the folder. The
purpose of the re-check is to flag any syntax errors that were not being caught by 1.x versions and to update the folder to
support the new functionality provided in VersaPro 2.0x. It is recommended that you select Yes, perform a check all on the
folder and correct any syntax errors. After going through this process, the message will not be presented the next time the
folder is opened. To avoid inequality issues with the PLC, it is recommended that you open hardware configuration, save it in
the new format and store your logic to the PLC. These operations are required because new functionality has been added to the
VersaPro 2.0x folders. However, the program and configuration are functionally equivalent to what was previously stored to
the PLC using VersaPro 1.x.
If you open a folder created in a previous version of VersaPro, select Yes to the message below and re-check it, you will not be
able to reopen the folder in the VersaPro build it was created in.
Selecting No will not force you to re-check the folder or correct any syntax errors. In addition, you will be able to gain equality
with the PLC and monitor existing logic. However, the dialog shown below will appear each time the folder is opened and the
logic portion of the folder will be in a read only state and will allow only limited operations.
Logicmaster 90-70 Folder Import Procedures
If you have a Logicmaster 90-70 folder created before Release 6 of Logicmaster, you should use the following procedure to
import your Logicmaster folders into VersaPro:
1. Open Logicmaster 90-70 Release 6 or greater.
2. Press F1 to enter programming mode and select any folder.
3. Press F8 (Program Folder Functions) and then F1 (Select/Create a Program Folder).
4. Select the folder to be imported into VersaPro followed by Ctrl-T. You will see a message “Converting old logic files to
new format, please wait ...” followed by “File conversion complete; press any key to continue”.
5. In VersaPro, create a new folder based on the Logicmaster folder.